Loading...
Automatic Maintenance Function
5-21
1
1
1
5
Routine Maintenance
Setting the Tube Washing Intervals
The interval between each operation of washing the cap and PUMP tube with cleaning solution for
maintenance is set.
1
Select [AUTO MAINT.] of the maintenance menu.
(1) Press the key in LOCAL.
(2) Press to select [MAINTENANCE] and press the key.
(3) Press to select [AUTO MAINT.].
(4) Press the key.
2
Press to select [PUMP TUBE WASH].
3
Press the key.
4
Press to set the interval between each
PUMP tube washing operation.
Set value : OFF or 1 to 168 hours
5
Press the key.
6
Press the key several times to end the setting.
AUTO MA I NT .
PUMP TUBE WASH < e n t >
AUTO MA I NT .
WA S H I N T E R V A L =
1 h
AUTO MA I NT .
WA S H I N T E R V A L =
4 h
AUTO MA I NT .
PUMP TUBE WASH < e n t >