I-88Di251/Di351 Rev. 1.1.0.0/03.01
left
If the measured width is not within the standard
values, use the following procedures for
adjustment.
7. Touch OK to complete the setting.
8. Select the Drawer to be adjusted.
9. Press the Clear key and enter the value from
the 10-key pad.
Pressing the ID key can change the “+” or “-”
sign alternately.
10. Make a test print again and check for correct
registration.
If the width of the measure margin does not meet
its standard width, follow the instructions
described below.
For Universal
Open the paper drawer for the Cassette that
needs to be adjusted, and then remove all of the
paper.
Loosen the two screws of the drawer.
watching the scale on the adjusting plate inside
the drawer, move the guide plate as necessary.
After the adjustment has been made, tighten the
screws and then produce a test print to check
again.