FrameMaker Ver5.5E(PC) Di251/Di351 MECHANICAL/ELECTRICAL
.05.03.01
M-19
11-3. Original Size Detection Timing
• Takes size readings:
When the Original Cover is raised to an angle of 15° or more (Original Cover Detecting
Sensor is unblocked).
• Affirms size readings:
When the Original Cover is lowered to an angle of 15° or less (Original Cover Detecting
Sensor is blocked) and the Size Reset Switch is actuated.
Or, when the Start key is pressed with the Original Cover Detecting Sensor unblocked.
• Resets size readings:
When the Original Cover is raised and the Size Reset Switch is just deactuated from the
actuated state.
Electrical Component Control Signal ON OFF Wiring Diagram
S6 CN9BCR-2 L H 15-D
Electrical Component Control Signal Activated Deactivated Wiring Diagram
PC14 CN10BCR-2 L H 15-C
1167M113AB
Original Cover Detecting
Sensor PC14
Size Reset Switch S6
Magnet