I-22Di251/Di351 Rev. 1.1.0.0/03.01
left
9. Reinstall the wiring cover (one screw).
1.6.3 Switching the tension strength of the automatic duplex unit wire
1. Remove the copier exit trag and switch the
green lever in the direction of the arrow.
NOTE
After the automatic duplex unit is installed,
opening the duplex unit may unbalance the
copier or cause it to shift position due to the
added weight. Be sure to switch the tension after
installation.
2. Reinstall the exit tray.
1.6.4 Reference Gap Adjustment
1. Access the service mode screen.
(Refer to the service manual.)
2. Press the stop key and then immediately
press the start key.
The Adjust Mode will be displayed.