(2) Removal of the CCD Unit
NOTES
When removing the CCD Unit, remove only those screws and parts that are specified.
(Remove the CCD Unit as one unit.)
Whenever the CCD Unit has been replaced, make the following adjustment:
FD of Zoom Adjust (IR).
(3) Cleaning of the Scanner Rails/Bushings
17. Remove three screws and the mounting bracket.
18. Remove four screws and the PH Unit.
4011D033AA
1. Remove the Original Glass.
2. Unhook the tabs of the cover in order of A, B, C,
and D and remove the cover.
A
D
D
B
C
4011D034AA
3. Unplug two connectors of the CCD Unit.
4. Remove two screws and the CCD Unit.
4011D035AA
1. Remove the Original Glass.
2. Using a soft cloth, wipe clean the Scanner Rails
and Bushings.
4011D036AA