FrameMaker Ver.5.5E(PC) Di251/Di351 DIS/REASSEMBLY, ADJUSTMENT
05.03.01
D-23
17. Peel off the tape from the pulleys at the front and rear.
18. Loosen one screw that secures the spring mounting bracket. Using a bar tension gage,
pull the mounting bracket with a force of 1,300
± 100 g. Keeping this condition, tighten
the mounting screw.
20. Mount the Scanner.
21. Reinstall the Reinforcement Bracket.
22. Reinstall the cover.
23. Mount the Original Size Detection Sensor.
24. Reinstall the Left IR Cover.
25. Reinstall the Original Glass and Left Upper Cover.
26. Perform the Focus-Positioning of the Scanner and 2nd/3rd Mirrors Carriage.
See "3-6. FOCUS-POSITIONING OF THE SCANNER AND 2ND/3RD MIRRORS CAR-
RIAGE."
NOTE
Whenever the Scanner Drive Cables have been removed, be sure to make the following
adjustment: CD of Zoom Adjust (IR).
16. Fit the hook end of the cable into the groove in
the Cable Guide and hook the spring.
4011D053AA
Cable Guide
4011D106AB
FrontRear
4011D055AB
Front
19. Press the 2nd/3rd Mirrors Carriage tightly up
against the front and rear rails. Perform the
Focus-Positioning of the Scanner and 2nd/3rd
Mirrors Carriage using the drive cable adjusting
screws at the front and rear so that there is a
clearance of "0."