18. Remove one shoulder screw and the Fusing
Guide Assy.
19. 1Remove one screw, one shoulder screw, and
the cover.
4011D072AB
20. Snap off one retaining ring E type and remove
the Front Pressure Lever Assy and bearing.
4011D073AA
21. Snap off one retaining ring E type and remove
the Rear Pressure Lever Assy and bearing.
22. Remove the Right Fusing Roller.
4011D074AB
23. Remove three screws, frame, spring, and the
lever.
4011D075AB
4011D076AB
NOTES
Study the illustration for how the spring is installed.
After the spring has been installed, move the lever
inthedirectionofthearrowtomakesurethatitis
returned by the tension of the spring.