FrameMaker Ver5.5E(PC) Di251/Di351 SWITCHES ON PWBs/TECH. REP. SETTINGS
05.03.01
S-49
Mode Initial value
418
76543210
Bit: 01111000
HEX: 78
Bit Function
Logic
Description
01
7
Fixed Setting change inhibit
6 Edge Erase
Bit6-5: 00 0 mm
When a BS scan (including
ADFR) is performed
1. In the APS/AMS mode,
exactly the width set from the
detected original size frame
is erased.
2. In the manual mode, exactly
the set width from the frame
of the read range determined
by the paper size and the
magnification is erased
(white mask).
• Does not function during an
NADF read operation.
• Functions in all modes.
5011mm
10 2 mm
11 3mm
4 I/C Life Stop Specification Stop Do not
stop
Sets whether to stop or not stop a print opera-
tion when the imaging unit reaches the end of
its life.
3 I/C Near-End-Of-Life Display
Setting
Do not
display
Display Sets whether or not to display the fact that the
imaging unit is approaching the end of its life.
2-0
Fixed Setting change inhibit
Mode Initial value
421
MC
76543210
Bit: 00100000
HEX: 20
MH
76543210
Bit: 01000000
HEX: 40
Bit Function
Logic
Description
01
7-5 Destination Code (copy) Bit5-3: 000 MSJ Changes set values such as
paper size and magnification.
MC initial value: 001
ME initial value: 010
001 MC
010 ME
011 Other
100
Line
adjust-
ment
Other
Setting
inhibit
4-0
Fixed Setting change inhibit