FrameMaker Ver.5.5(PC) Di251/Di351 TROUBLESHOOTING
05.03.01
T- 3 2
For the printer controller malfunctions of C18XX, see Pi3502 service manual.
Code Description Detection Timing
C1300 Polygon Motor malfunc-
tion
<Faulty start detection>
The Lock signal is not detected at any time during a
given period of time 1 sec. after the Polygon Motor
has been energized.
<Faulty Lock signal detection>
No Lock signals are detected at any time during the
1-sec. period which starts 1 sec. after the first Lock.
<Out-of-timing Lock detection>
The Lock signal is not detected for a continuous 0.5-
sec. period while the Polygon Motor is in the stabi-
lized turning state.
<Abnormal Lock detection>
The Lock signal remains ON for a continuous 5-sec.
period while the Polygon Motor remains deener-
gized.
C133A Communications error
(G/A)
Communications with the gate array for expansion I/O
(the IC mounted on the Master Board) fail.
C133B Communications error
(option I/F)
The connection status of a finishing option is changed
after the power has been turned ON.
C13C0 I/C initialization failure After failing to blow the imaging cartridge fuse two
consecutive times, the I/C is determined to be new.
C13D0 Faulty EEPROM EEPROM, in which no initial data is written, is found.
C13F0 HSYNC detection failure The SOS falling edge is not detected for 0.2 sec. or
more after the Polygon Motor has been energized
and laser output started.
No SOS falling edges are detected while VIA
remains ON.