Test Check List
Table 22: Test Setup for 350–470 MHz Radio Models
The following table summarizes the required test setup for 380–430 MHz radio models.
Test Name Test Setup Radio Setup Test Conditions Limits
Base Station Reg-
istration
Control Channel 390.125 MHz 3605 TETRA 380+0MS
Traffic Channel 390.125 MHz 3605 TETRA 380+0MS
Time Slot N/A 3 N/A
Country Code N/A 234 N/A
Network Code N/A 2392 N/A
Base Color N/A 1 N/A
Location Area N/A 22 N/A
Min Rx Level N/A N/A –110 dBm
Max Tx Level N/A N/A 30 dBm (Class 4)
32.5 dBm (Class
3L)
34.5 dBm (Class
3)
Access Parameter N/A –53 dBm N/A
Mobile Power 30 dBm (Class 4) N/A N/A
32.5 dBm (Class
3L)
34.5 dBm (Class
3)
Burst Type N/A Normal N/A
Transmitter Burst
Power
RF Gen Level
Burst Power
N/A –90 dBm 28–32 dBm
(Class 4)
30.5–34.5 dBm
(Class 3L)
32.5–36.5 dBm
(Class 3)
Timing Error N/A N/A ±0.25 Symbols
Vector Error N/A N/A Max 10% RMS,
30% Peak
Frequency Error N/A N/A ±100 Hz
Call Processing
Talk Back
1 kHz Test Signal
Group Mode
N/A –50 dBm N/A
Call Processing
Call to Mobile
Private 4 digit random
number and Send
N/A 28–32 dBm
(Class 4)
68015000841-EL