EasyManua.ls Logo

Motorola solutions MTP3100 - Configuring IFR 2968 Setup

Motorola solutions MTP3100
143 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NEIGHBOUR CELL CHANNEL: 3500
NEIGHBOUR CELL LOCATION AREA: 0017
NEIGHBOUR CELL IDENTIFIER: 01
SLOW RE-SELECT THRESHOLD ABOVE FAST: 10 dB
FAST RE-SELECT THRESHOLD: 10 dB
SLOW RE-SELECT HYSTERESIS: 10 dB
FAST RE-SELECT HYSTERESIS: 10 dB
16. Press CONFIG. Select Call Timers & Trunking.
17. Select Transmission for Trunking Type.
18. Select Continuous for Test Set Transmit Mode.
4.5
Configuring IFR 2968 Setup
Use these procedures to configure the IFR 2968 setup.
Procedure:
1. Turn ON the IFR.
2. Press Systems Mode Key and wait until the digital system is initialized.
3. Press Tetra MobileSetup. Enter the System Parameters Screen.
4. Press Channel Plan.
5. Perform one of the following actions:
For MTP3100/3150/3200/3250 Version A 350–430 MHz radios, press 380+0MS.
The Control Channel automatically changes to 3600, and Traffic Channel automatically changes
to 3700.
For MTP3100/3150/3200/3250 Version A 806–870 MHz radios, press 380+0MS.
The Control Channel automatically changes to 2040, and Traffic Channel automatically changes
to 2140.
For MTP3100/3150/3200/3250 Version B and MTP3500/3550 350–470 MHz radios, press Tetra
380+0MS.
The Control Channel automatically changes to 3600, and Traffic Channel automatically changes
to 3700.
For MTP3100/3150/3200/3250 Version B and MTP3500/3550 806–870 MHz radios, press Tetra
800MS.
The Control Channel automatically changes to 2040, and Traffic Channel automatically changes
to 2140.
6. Press Traffic ChannelTraffic Channel. Check that the marker goes to Timeslot.
7. To change to Timeslot 3, press 3Traffic Channel.
8. Press Country Code. Enter 234 and press Country Code.
9. Press Network Code. Enter 2392 and press Network Code.
10. Press Base Color. Enter 1 and press Base Color.
11. Press More.
12. Press Location Area. Enter 22 and press Location Area.
13. Press More.
14. Press Min Rx Level. Enter -110 dBm and press Min Rx Level.
68015000841-EL