Spark plug operating hours above threshold / below threshold
Warning active
Error active
Temperature above threshold / below threshold
Analog voltage input over threshold / under threshold
Analog current input over threshold / under threshold
Global ignition timing above the threshold / below the threshold
Supply voltage above threshold / below threshold
Min. spark duration above threshold / below threshold
Misfire rate (primary, single output) over limit
Misfire rate (primary, all outputs) over limit
Misfires per second (primary, all outputs) above threshold
Consecutive misfires (primary, single output) above threshold
Misfire rate (secondary, individual output) above threshold
Misfire rate (secondary, all outputs) above threshold
Misfires per second (secondary, all outputs) above threshold
Consecutive misfires (secondary, single output) over the limit
Threshold
Input of desired threshold value.
Hysteresis
Input of desired hysteresis value.
Delay
Input of desired delay. The threshold value defined in the alarm must have been exceeded or
not reached for a longer period than the specified time for an alarm to be triggered. If a
corresponding value occurs for a shorter period of time, no alarm is triggered.
Engine Shutdown
If this checkbox is checked, the ignition is switched off as soon as the alarm is triggered.
The shutdown causes an operational error. Therefore the checkbox should not be checked, if
the alarm Error active is selected.
Permanent – Keep output activated until alarm is acknowledged
If this box is checked, the output remains permanently active until the alarm is
acknowledged. If the box is not checked, the output remains active only for as long as the
alarm is active.
Log Events
If this box is checked, the event list records when the alarm occurred or when it was
acknowledged.