8 Settings via the MICT
Rev. 03/2019 85
Compatibility of the configuration files
Configuration files are only compatible for the respective device type, even
if the file extension is identical. For example, files created for a MIC3 cannot
be downloaded to a MIC3+ and vice versa.
To use a configuration for another device, the series and the first four digits
of the arrangement number must match. This information can be found in
the title bar of the configuration and on the respective device:
MIC3
MIC3+
If, for example, a system is to be changed from a MIC3 to a MIC3+, the
configuration of the MIC3 can be saved as a PDF file. Then a new
configuration file must be created for the MIC3+ and the values from the
PDF file must be entered. Alternatively, the MICT can be opened twice and
the values transferred to a newly created configuration file.
8.10.2 Upload, Download
Click the symbol to upload the current configuration from the MIC5 to the MICT.
If applicable, the MICT first establishes a connection to the MIC5 connected.
Click on the symbol to download the configuration set in the MICT to the MIC5.
This function can only be executed while the ignition is not active. This action
overwrites the existing configuration on the device. If applicable, the MICT first
establishes a connection to the MIC5 connected.