EasyManuals Logo

Motortech MIC5 User Manual

Motortech MIC5
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #147 background imageLoading...
Page #147 background image
8 Settings via the MICT
Rev. 03/2019 147
8.14.4 Runtime Adjustments – Secondary Voltage Estimation Calibration
The secondary voltage estimation can be calibrated in this window when using ignition coils that
support this function:
A correction value without units can be set for the secondary voltage estimation for every output
to increase the accuracy of the secondary voltage estimation for each individual cylinder. This
allows, for instance, different cable lengths on the engine to be compensated.
The secondary voltage estimation should be calibrated under full load at a nominal speed. The
adjustment can be made using the relevant global or individual cylinder buttons. The value
range depends on the set ignition coil. 0.0 is set as the standard value for all cylinders.
Changes are implemented immediately and stored in the configuration provided in the device.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motortech MIC5 and is the answer not in the manual?

Motortech MIC5 Specifications

General IconGeneral
BrandMotortech
ModelMIC5
CategoryController
LanguageEnglish

Related product manuals