8 Settings via the MICT
Rev. 03/2019 133
8.12.6.2 Warnings
Contrary to errors, warnings do not result in the engine being shut down.
Warning Description
Configuration data checksum
error. Using default configuration.
The checksum of the configuration data is faulty. The
default configuration is used. This message may appear
during an upgrade/downgrade of the firmware. Check
your configuration data and the MICT version being used.
Then download the configuration to the device once
again.
Configuration invalid. Using
previous configuration.
The configuration is invalid. The previous configuration is
used. This message may appear during an
upgrade/downgrade. Check your configuration data and
the MICT version being used. Then download the
configuration to the device once again.
Disable secondary diagnostic due
to output Anumber/Bnumber.
Secondary diagnosis disabled due to output
Anumber/Bnumber shut off. Check the ignition coil and
wiring at the corresponding output.
General warning number. General warning number. An undefined warning has
occurred. If this occurs repeatedly, please contact
MOTORTECH.
Incompatible coil parameters
received, secondary voltage
diagnostics disabled.
Incompatible coil parameters received. The secondary
voltage diagnostics have been disabled. This message
may appear during an upgrade/downgrade. Check your
configuration data and the MICT version being used. Then
download the configuration to the device once again.
Invalid coil data received. Invalid coil data received. This message may appear
during an upgrade/downgrade. Check your configuration
data and the MICT version being used. Then download the
configuration to the device once again.
Pickup configuration invalid. The pickup configuration is invalid. This message may
appear during an upgrade/downgrade. Check your
configuration data and the MICT version being used. Then
download the configuration to the device once again.
Power output (x W) exceeded limit
(y W) at a supply voltage of z V.
The power output (x W) exceeded warning threshold limit
(y W) for longer than two minutes at a supply voltage of
z V .