8 Settings via the MICT
132 Rev. 03/2019
Information Description
J1939 on interface CANnumber
changed state to "name".
J1939 on interface CANnumber changed state to "name".
Following statuses are possible:
– Enter/Start succeeded
The CAN mode J1939 or ALL-IN-ONE (J1939) was
started.
– Start failed
Initialization failed.
– Stop
Assignment of the Source Address was unsuccessful.
A different source address needs to be set in the
configuration (see Miscellaneous – Communication
on page 111).
– Leave
Left CAN mode J1939 or ALL-IN-ONE (J1939).
One or more messages are lost
due to exhausted memory pool or
message queue overrun.
One or more messages were lost because there was
insufficient storage space or too many messages were
queued.
Operational error acknowledged. Operating errors are acknowledged.
PIN of access control level
"number" changed.
PIN of access control level "number" changed (see Access
Control for MIC5 on page 81).
Self test denied because no
outputs are configured.
The self test could not be carried out because no outputs
are configured (see Self Test on page 77).
Self test started. The self test was started (see Self Test on page 77).
Self test stopped. The self test was stopped (see Self Test on page 77).
Spark plug operating hours set to
x h.
The spark plug operating hours were set to x h.
Speed (x RPM) exceeded maximum
allowed speed (yRPM) at
power-on. Waiting for engine stop.
Speed (x RPM) has exceeded the maximum speed (
RPM)
during operation. The ignition controller is waiting for the
engine to stop.
Wrong pickup signal polarity on
pickup input PUnumber detected.
Reversing polarity internally.
Wrong pickup polarity detected at pickup input
PUnumber. Reversing polarity internally.