8 Settings via the MICT
Rev. 03/2019 131
Information Description
Device (firmware
number.number.number.number)
started at a supply voltage of x V.
The device (firmware number.number.number.number)
was started with a supply voltage of x V.
Device reset requested by
GPInumber failed because pickup
signals have been detected.
The device reset requested by GPInumber failed because
pickup signals have been detected (see Inputs/Outputs –
Inputs on page 110).
Device switched off. The device was switched off.
Engine operating hours set to x h. The engine operating hours set to x h.
Failed to change PIN of access
control level "number".
Failed to change PIN of access control level "number" (see
Access Control for MIC5 on page 81).
Failed to disable access control. The access control could not be disabled (see Access
Control for MIC5 on page 81).
Failed to enable access control. The access control could not be enabled (see Access
Control for MIC5 on page 81).
Failed to reset all access control
PINs.
Failed to reset all PINs for access control (see Access
Control for MIC5 on page 81).
Firing disabled (Start/Stop In:
value, CAN: value, RS485: value)
The firing is disabled, because at least one of the inputs
(start/stop input, CAN interface, RS485 interface) used for
the firing release is disabled. The inputs can have the
following values:
– enabled: Firing enabled
– disabled: Firing disabled
– n/a: not used
Firing enabled (Start/Stop In:
value, CAN: value, RS485: value)
The firing is enabled, because all inputs (start/stop input,
CAN interface, RS485 interface) used for the firing release
are enabled. The inputs can have the following values:
– enabled: Firing enabled
– disabled: Firing disabled
– n/a: not used