EasyManua.ls Logo

Motortech MIC5 - Runtime Data - Diagnostics

Motortech MIC5
172 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 Settings via the MICT
138 Rev. 03/2019
8.12.7 Runtime Data – Diagnostics
The following information is provided:
CAN State
The status display indicates the current error handling status of the device for the CAN bus
communication:
Error Active
The device is in normal status of the bus communication. If an error occurs in the
communication, the device sends an active Error Flag.
Error Passive
After a defined number of errors in the bus communication, the device changes to the
status Passive Error. If another error occurs, the device sends a passive Error Flag.
Bus Off
The device is disconnected from the CAN bus due to error accumulations in the bus
communication.

Table of Contents

Related product manuals