8.12.7 Runtime Data – Diagnostics
The following information is provided:
CAN State
The status display indicates the current error handling status of the device for the CAN bus
communication:
Error Active
The device is in normal status of the bus communication. If an error occurs in the
communication, the device sends an active Error Flag.
Error Passive
After a defined number of errors in the bus communication, the device changes to the
status Passive Error. If another error occurs, the device sends a passive Error Flag.
Bus Off
The device is disconnected from the CAN bus due to error accumulations in the bus
communication.