8 Settings via the MICT
Rev. 03/2019 139
– Controller Board
– Supply Voltage
Current voltage supply of the controller board.
– Pickup Input Pre-Trigger Voltage
Current pre-trigger voltage for the pickup inputs (refer to Engine – Pickups on page 96).
During operation the pre-trigger voltage for passive pickups is increased depending on
the speed, so that the ignition controller is less prone to interferences.
– Aux. Pickup Supply Voltage
Current auxiliary supply voltage of the pickups (refer to Engine – Pickups on page 96)
– Aux. Analog Input Supply Voltage
Current auxiliary supply voltage of the analog inputs (refer to Timing – Analog Inputs on
page 100)
– Output Board
– Power Output
Current output of the output board