Rev. 03/2019 167
11.1 Maintenance Instructions
Please follow the following maintenance instructions:
Do not use caustic liquids or steam cleaners for cleaning the device.
Clean the passive pickups at regular intervals.
Check the ignition wires at regular intervals.
Replace the pickups at regular intervals if operating them under elevated temperature
conditions (> +90 °C / > +194 °F).
Regularly inspect all wires of the ignition system for damage and replace the wires as
needed.
Check all plug-in connections for proper condition.
Service the spark plugs as per the instructions of the spark plug and engine manufacturers.
Observe the required tightening torques:
All M4 bolts: 0.8 Nm to 1 Nm (0.6 lb-ft to 0.7 lb-ft)
PG screw joints: 4.5 Nm to 5 Nm (3.3 lb-ft to 3.6 lb-ft)
Service screw: 2.5 Nm to 3 Nm (1.9 lb-ft to 2.2 lb-ft)
11.2 Spare Parts and Accessories
For spare parts and accessories for MIC5 ignition systems, please refer to our current product
guide, which is available for download on the Internet at www.motortech.de.