8 Settings via the MICT
Rev. 03/2019 119
8.12.3 Runtime Data – Ignition
The following information is provided:
Column: Output
Designation of the output
Column: Cylinder
If cylinder names are assigned, these are displayed.
Column: Estimated Secondary Voltage [kV]
Secondary voltage determined by the ignition controller of the respective output.
The secondary voltage is used to determine deviations between the individual outputs.
These indicate a possible problem at this output (e. g. problems in the area of the spark plug
or the cylinder).
If you have set the ignition coils (refer to Engine – Ignition Coils on page 94) for which a
secondary voltage estimate does not seem possible "---" appears.

Table of Contents