8 Settings via the MICT
Rev. 03/2019 129
In the view Message Log, information, warnings, errors and alarms are listed.
Information, warnings and errors are specified by the ignition controller, while alarms can be
freely configured using the MICT. Refer to the section Inputs/Outputs – Alarms on page 106.
Errors and appropriately configured alarms shut down the engine.
The following information is provided:
Operating Hours
Operating hours counter reading at the time of message
Time
Date and time of the message (see following information box)
Category
Type of message (information, warning, error, alarm)
Message
Message text; you can find more information on the message text in the following sections.
You have the following options:
Automatic scrolling
If this box is checked, the system automatically displays the last list entry until a new event
occurs.
Acknowledge Alarms
With this button, you can reset triggered alarms if they are no longer active. An alarm can
only be acknowledged if the checkbox Permanent – Keep output activated until alarm is
acknowledged in the alarm configuration is activated.
Date and time of ignition controller
The date and time can be individually configured for each ignition controller
and saved in the device. The device does not adjust automatically for
daylight savings time. Hence, deviations may occur between the device
time and the time on the computer used to access the device.
Correspondingly, the times indicated for the states, messages, and in the
log reflect the time of the ignition controller. The current time of the ignition
controller is shown in the view Runtime Data – Information. You can adjust
the time of the ignition controller by entering the desired time in the menu
via Device -> Set date and time.