8 Settings via the MICT
156 Rev. 03/2019
Coil Parameters
The following information is provided:
Max. Breakdown Voltage [kV]
Displays the permitted value range for the maximum breakdown voltage in kV. The
maximum breakdown voltage is configured in the view Ignition Timing – Schedule A/B
Energy (refer to Timing – Schedule A/B – Energy on page 104).
Spark Intensity [mA]
Displays the permitted value range for the spark intensity in mA. The spark intensity is
configured in the view Ignition Timing – Schedule A/B – Energy (refer to Timing – Schedule
A/B – Energy on page 104).
Secondary Voltage Estimation Calibration
Displays the permitted value range for the secondary voltage estimation calibration. The
calibration of the secondary voltage estimation takes place in the view Engine – Ignition
Coils (refer to Engine – Ignition Coils on page 94) and in the runtime adjustments (refer to
Runtime Adjustments – Secondary Voltage Estimation Calibration on page 147).
Secondary Short Sensitivity
Displays the permitted value range for the calibration of the secondary short sensitivity. The
calibration of the secondary short sensitivity takes place in the view Engine – Ignition Coils
(refer to Engine – Ignition Coils on page 94) and in the runtime adjustments (refer to Runtime
Adjustments – Secondary Short Calibration on page 148).