PAGE 88 — RX1575 SERIES TRENCH ROLLER • OPERATION MANUAL — REV. #0 (04/28/15)
114 Rammax 1575
1230047 | 21.06.2013
13.1 Introduction
The roller must be disposed of properly; ask your authorized dealer.
13.2 Removal and depressurization of the gas strut
In case of disposal, pressurized gas struts must be depressurized according to the
following regulations:
1 Fasten the pressurized tube between two prismatic jaws without deforming it
and in such a way that the dimension X is at least 25mm (see below).
2 To depressurize:
2a Slowly cut the pressurized tube open at the points indicated using a handsaw
or,
2b Drill a hole in the tube using a drill with about a 3 mm diameter.
CAUTION
Environmental hazard through operating materials!
• Do not allow any liquids to enter drains, the soil or the environ-
ment.
WARNING
Eye injury!
Because of the high internal pressure, chips and oil can spat-
ter from the site of sawing or drilling.
• Wear eye and face protection.
• Cover the site of the saw cut.
CAUTION
Environmental hazard through operating materials!
Gas struts are filled with oil.
• Do not allow any liquids to enter drains, the soil or the environ-
ment.
DISPOSAL