EasyManua.ls Logo

Nordson PURBlue EC - Material Pressure too High

Nordson PURBlue EC
182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
6-13
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
Material Pressure too High
Problem Possible Cause Corrective Action
1. Safety valve or
pressure control
valve dirty and thus
blocked
Safety valve: Replace
Pressure control valve: Disassemble
and clean or replace
2. Safety valve or
pressure control
valve defective
Replace
3. Pressure control
valve set incorrectly
Set to default
Material Pressure too Low
Problem Possible Cause Corrective Action
1. Pump is worn Replace pump
2. Safety valve does not
close any more
Replace
3. Pressure control
valve dirty and thus
clogged
Disassemble and clean or replace
4. Pressure control
valve defective
Replace
5. Pressure control
valve set incorrectly
Set to default
Material Residue or Hardened Material in Tank
Problem Possible Cause Corrective Action
1. Tank setpoint
temperature set too
high
Correct temperature setting
Material of low quality or not
appropriate for application
(temperature resistance poor)
Consult material supplier
2. No inert gas Refer to No Inert Gas
3. Inert gas interval set
incorrectly
Check settings on timer relay
4. Unsuitable inert gas Consult material supplier

Table of Contents