Operating Parameters
B-16
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
Seven-day Clock
Refer to Functions and Function Keys in the section Operation.
Setting Internal Clock (Realtime Clock)
1. Enter the current day of the week with parameter 50.
2. Enter the current time of day with parameter 51.
Creating Schedule
NOTE: In order for the clock to operate continuously throughout the week,
a control option must be assigned to every day of the week (parameters 71
to 77).
Up to three schedules can be assigned for each day (to support three work
shifts).
To prevent unintentional activation of the seven-day clock, the default
setting for parameters 71 to 77 is control option 0. If the Seven-day clock
key is pressed unintentionally in this setting, the melter is not affected.
3. Create schedule 1:
a. Set parameters 55 and 56 to the time of day that the heaters should
turn on and off.
b. Set parameters 57 and 58 to the time of day that the melter should
enter and exit standby mode.
4. Repeat step 3 to create schedules 2 and 3 with parameters 60 to 68.
5. Determine which control options should apply to each day of the week
with parameters 71 to 77.
6. Press the Seven-day clock key to enable the clock.