Operation
4-8
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
Saving and Restoring Settings
The current value of all editable operating parameters and the setpoint
temperature of each component can be saved and restored at a later time.
NOTE: If the restore feature is used before the save feature is used for the
first time, the original state will be restored. Hoses and guns will then stop
heating; their setpoint temperature is 0 degrees (= switched off).
Saving All Current Settings
With the system in normal mode, simultaneously press the number key 1
and the Setup key.
S-1 appears briefly in the right display.
Fig. 4-4
Restoring Saved Settings
CAUTION: The settings currently in use are overwritten! Before restoring
saved settings, ensure that use of the restored settings will not disrupt the
current process or create unsafe operating conditions.
With the system in normal mode, simultaneously press the number key 2
and the Setup key.
S-2 appears briefly in the right display.
Fig. 4-5
Saving Multiple Variations of Melter Settings
A PC and the Nordson Configuration Manager are needed. Refer to
Appendix C, Melter Communication for detailed information.