EasyManua.ls Logo

Nordson PURBlue EC - Functions and Function Keys; Standby; Manual Entry;Exit with the Key; Automatic Exit Via Parameter 26

Nordson PURBlue EC
182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
4-22
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
Functions and Function Keys
Standby
Standby serves to protect the hot melt material and to save energy during
breaks in production.
The melter can be set up to automatically enter standby using a series of
parameters (Refer to Appendix B, Parameters 25, 26, 30–33, 57, 62 and
67) or standby can be entered manually with the key Standby.
When the melter enters standby, the temperatures of all components are
reduced from their setpoint temperatures by a preset standby delta.
Manual Entry/Exit with the Key
The melter enters or exits standby mode when the key Standby is pressed.
Automatic Exit via Parameter 26
Parameter 26 is the amount of time that the melter remains in standby
mode after the Standby key is pressed. When the parameter is enabled, the
LED in the Standby key flashes,
After the time has expired, the melter once again begins heating all of the
components to their assigned setpoint temperatures.
Automatic Entry/Exit via the Seven-day Clock
Refer to Appendix B for detailed information on setting up the seven-day
clock.

Table of Contents