Repair
7-13
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
Replacing Control Panel (Service Kit)
NOTE: The software need not be installed again.
Fig. 7-14 Contents of kit
WARNING: Risk of electrical shock. Failure to observe may result in
personal injury, death, or equipment damage.
1. Set the main switch to 0/OFF.
WARNING: Disconnect equipment from the line voltage.
2. Open the electrical cabinet door.
3. Unplug the ribbon cable from the old control panel.
M4
4. Release the M4 hexagon nuts and remove with the tooth lock washers.
5. Press old control panel and old seal forwards and out of the electrical
cabinet door.
6. Insert new control panel with new seal.
7. Screw on new control panel. Use tooth lock washers.
8. Plug the ribbon cable into the new control panel.
9. Close the electrical cabinet door.