Checking Actual Temperature Manually
1. Press the key that represents the component group to be checked. The
automatic scan cycle stops.
S When the tank key is pressed, the left display does not show a
component number (blank display). The right display shows the
reservoir’s actual temperature.
Reminder: If the tank key is held down for three seconds, the left
display flashes 1. The right display shows the reservoir’s setpoint
temperature.
S If the key for a different component group is pressed, the left display
indicates the number of the first component in the selected
component group. The right display shows the component’s actual
temperature.
Fig. 4-8
2. If the first sequential component is not the component to be checked,
use the left display scroll key to move to the correct component number.
When you scroll past the number of the last sequential component in a
component group, the number of the first component in the next group
appears.
3. The melter returns to normal mode two minutes after the last key is
pressed.
Or press Setup twice to immediately return to normal mode.
Helpful Information
S Briefly press the tank key to check the actual temperature of the
reservoir.
S To check the actual temperature of the grid, simultaneously press the
Tank key and the left display scroll key.
S Call up Hose 5 to check the actual temperature of the hopper.