Operating Parameters
B-15
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
Output Setup (contd.)
Optional Outputs
43 46 Optional Outputs 4, 5, 6, and 7 Not Shown
Description:
Control options that determine the function of the four optional outputs,
provided the optional I/O expansion board is installed on the main board.
Value:
0 = Output disabled
1 = Ready
2 = Ready and pump running
3 = Fault
4 = Tank low level (only when melter has level scan feature)
5 = Service LED on
6 = Alarm
Resolution:
1
Default:
0 (all optional outputs)
Format:
Use:
Refer to the instruction sheet provided with the optional I/O expansion board for
information about wiring and setting up the optional outputs.