Maintenance
5-10
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
Important for Mechanical Pressure Control Valve
Measuring Insertion Depth
Measure and make a note of the insertion depth of the setting screw
(dimension X). This way the insertion depth can be replicated after
reassembly.
Fig. 5-6
Adjusting Pressure Control Valve
The setting screw is secured with the locknut (1, Fig. 5-6).
1. Loosen the locknut.
2. Adjust the setting screw to the recorded dimension X.
S Turning to the right increases material pressure.
S Turning to the left decreases material pressure (Fig. 5-7).
3. Tighten the locknut.
Fig. 5-7 Reduce pressure
Tank
NOTE: The inside of the tank is release coated. Do not use metallic tools to
clean. Do not use wire brushes! This could damage the release coating.