Installation
3-15
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
Installing Gun
Refer to the gun manual.
CAUTION: The maximum operating temperature of the installed gun and
the other heated components should be considered when setting
temperatures on the melter control panel.
Conditioning Compressed Air for Gun Control Modules
The quality of the compressed air must be at least class 2 in compliance
with ISO 8573−1. This means:
S Max. particle size 1 mm
S Max. particle density 1 mg/m
3
S Max. pressure dew point − 40 °C
S Max. oil concentration 0.1 mg/m
3
.
Removing Melter
Run the melter until empty, separate all connections from the melter, and
allow the melter to cool down.
Disposing of Melter
When your Nordson product has exhausted its purpose, dispose of it
properly according to local regulations.