Operation
4-6
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
Setting Operating Parameters
Operating parameters are stored in the melter’s firmware as a sequentially
numbered list. Refer to Appendix B.
In addition to the ability to read and edit parameter values, you can also
save and restore the current value of every operating parameter and call up
a log of the last ten changes that were made.
1. Press the Setup key.
Parameter 1 flashes in the left display.
2. Use the keypad to enter the desired parameter.
NOTE: If you incorrectly enter the parameter number, press the
Clear/Reset key to return to parameter 1, then re-enter the correct
parameter number.
When you have finished entering the one- or two-digit parameter
number, the right display indicates the parameter’s current value.
3. Press the Enter key.
The right display flashes.
4. Use the keypad to enter the value in the right display.
NOTE: If the information you entered does not appear in the right
display, the melter is protected by a password. You must enter a valid
password before parameter values can be edited. Refer to Entering
Password.
You can also use the right display scroll keys to change a parameter’s
value. After entering the parameter number in the left display, press
either of the right display scroll keys to change the value.
5. Press the Enter key.
The melter checks the validity of the new value.
S If the parameter value is accepted, the left and right displays show
the next parameter number and value.
S If the parameter value is not accepted, the right display shows
dashes (----) for three seconds and then changes back to the original
value.
6. Press the Setup key to exit Setup mode.