Operation
4-12
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
Change History Log
Calling Up Change History Log
The melter stores in a change history log a record of the last ten changes
that were made to either operating parameters or setpoint temperatures.
1. Press the Setup key.
Parameter 1 flashes in the left display.
2. Press the left display scroll key to change the display to parameter 3 (to
change history log).
S If the last change was to an operating parameter, all of the
component key LEDs remain off.
S If the last change was to a setpoint temperature, the LED on the
associated component key(s) turns on.
The right display shows the four-digit log entry associated with the last
change that was made.
Refer to Structure of Change History Log.
3. Press the right display scroll key to review each of the remaining nine
log entries. Each time a scroll key is pressed, a progressively older log
entry appears.
4. To see how many hours the heater has been operating since a certain
(displayed) change, press both right display scroll keys simultaneously.
5. Press the Setup key to return to normal mode.