1
2
2
1
3
Introduction
2-5
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
Safety Valve Plate
The safety valve plate can be slid in the groove to perform maintenance and
repair work. Refer to section Maintenance, Releasing Safety Valve Plate
and Securing Safety Valve Plate.
Safety Valve
The standard safety valve (1) is fixed at
85 bar 8500 kPa 1235 psi.
When the pressure is exceeded, the safety valve opens, allowing the
material to circulate within the safety valve plate.
Pressure Control Valve
The mechanical pressure control valve (2) can be manually adjusted up to
75 bar 7 500 kPa 1100 psi.
Plug
The plug (3) seals the material drain bore.
Fig. 2-4
Heating Plate
The heating plate is right next to the safety valve plate and warms it by
conducting heat. The heating plate remains in place when the safety valve
plate is moved.
For control purposes, the heating plate belongs to the reservoir.
Fig. 2-5