Operating Parameters
B-23
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
Timer for Automatic Filling
78 Timer Automatic Filling
Description:
A timer that counts down; it can be connected to a switch at one of the
inputs.
Value:
0 to 90 seconds
Resolution:
1
Default:
0 (disabled)
Format:
—
Use:
Used in conjunction with input control option 13 or 14. Activate output
control option 6 (alarm) to transmit a signal when the time has elapsed.
The operating parameter is not suitable for these melters.
Output (Control Option 3): Reversal of Fault Logic
79 Reversal of Fault Logic − Not Shown −
Description:
Reversal of fault output logic from Contact opens when fault occurs to
Contact closes when fault occurs.
Value:
0 or 1
Resolution:
—
Default:
0 (Contact opens when fault occurs)
Format:
—
Use:
Caution when reversing fault logic: Ensure that the parent machine can
not be endangered when a fault signal is received.
PID Selection
80−91 PID Selection for Hose/Gun 1, 2, ..., 6
Description:
Changes the default PID settings. Use parameter 80 to select the value for
hose 1, parameter 81 to select the value for gun 1, and so on.
Value:
0 = Hose
1 = Standard gun
2 = Large gun
3 = Air heater
Resolution:
1
Default:
0 or 1, depending on component (hose or gun)
Format:
—
Use:
Consult your Nordson representative before changing PID settings.
Original state: Operating parameter 88 (hopper) = 3