Operating Parameters
B-12
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
Input Setup (contd.)
32 Input 3
Description:
Control options that determine the function of input 3.
Value:
0 − Input disabled
1 − Standby on/off
2 − Heaters on/off
3 − Enable/disable motor 1
4 − Enable/disable hose/gun 1
5 − Enable/disable hose/gun 2
6 − Enable/disable hose/gun 3
7 − Enable/disable hose/gun 4
8 − Enable/disable hose/gun 5
9 − Enable/disable hose/gun 6
11 − Enable/disable motor 2
13 − Timer Automatic filling 1
14 − Timer Automatic filling 2
Resolution:
1
Default:
2
Format:
—
Use:
NOTE: Multiple inputs set to the same input value are logical ORed.
NOTE: To be able to use option 13 or 14, parameter 78 must be set to 1 or
higher. Output option 6 (alarm) can be used to signal that the timer has expired.
Option 13/14 is not suitable for these melters.
Original state: 3
33 Input 4
Description:
Control options that determine the function of input 4.
Value:
0 − Input disabled
1 − Standby on/off
2 − Heaters on/off
3 − Enable/disable motor 1
4 − Enable/disable hose/gun 1
5 − Enable/disable hose/gun 2
6 − Enable/disable hose/gun 3
7 − Enable/disable hose/gun 4
8 − Enable/disable hose/gun 5
9 − Enable/disable hose/gun 6
11 − Enable/disable motor 2
13 − Timer Automatic filling 1
14 − Timer Automatic filling 2
Resolution:
1
Default:
4
Format:
—
Use:
NOTE: Multiple inputs set to the same input value are logical ORed.
NOTE: To be able to use option 13 or 14, parameter 78 must be set to 1 or
higher. Output option 6 (alarm) can be used to signal that the timer has expired.
Option 13/14 is not suitable for these melters.
Original state: 1