Operating Parameters
B-21
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
Seven-day Clock (contd.)
68 Schedule 3 Exit Standby
Description:
Used to set the time that the melter will exit standby mode during schedule 3.
Value:
0000 to 2359, - - - -
Resolution:
1 minute
Default:
- - - -
Format:
Hour, Hour: Minute, Minute
Use:
To disable this parameter, set the parameter’s value to ”- - - -” by
simultaneously pressing both of the right display scroll keys.
Note: Do not set an exit standby time that is outside of the time period defined
by the schedule’s heater on and off time. The melter can not enter standby
mode when the heaters are off.
71−77 Control Options for the Days of the Week
Description:
Used to select which schedule(s) should be used on a certain day of the week.
Value:
0 – Remain at last clock transition
1 – Use only schedule 1
2 – Use only schedule 2
3 – Use only schedule 3
4 – Use schedules 1 and 2
5 – Use schedules 2 and 3
6 – Use schedules 1 and 3
7 – Use schedules 1, 2 and 3
Resolution:
1
Default:
0
Format:
—
Use:
Parameter 71 (Monday)
Parameter 72 (Tuesday)
Parameter 73 (Wednesday)
Parameter 74 (Thursday)
Parameter 75 (Friday)
Parameter 76 (Saturday)
Parameter 77 (Sunday)
Note: If control option 0 is used, e.g. the heaters will not turn on again until the
next scheduled Heater on time is reached. Refer to example 2.