Fig. 4‐32
V1
Operation
4‐39
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Melter
Entering/Exiting Standby
Refer to Control Panel - Overview - / V9 for information on standby setup.
Switching On/Off All Motors (Collective Enable)
Also refer to Initial Startup (Fig. 4‐10) and Motor Startup Protection.
Only enabled motors can be switched on. Prerequisite: The system is ready
for operation.
Enabling
If there is no individual enable, the motors are enabled with the key Switch all
motors on/off (collective enable) AND via the interface Standard I/O with the
signal All motors ON (collective enable).
Switching On
If there are individual enables, the motors are switched on with the key
Switch all motors on/off (collective enable) AND via the interface Standard
I/O with the signal All motors ON (collective enable).
The indication lamp in the key can be different colors:
Gray (off): No collective enable on control panel
Yellow: Collective enable on control panel, but no motor running
Green: Motor running.
1
2
Pump 1
Pump 2
Fig. 4‐33 Motor(s): Enable on the motor screen - switch on on the melter screen