Installation
3‐9
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Installing Applicator
Refer to the applicator manual.
CAUTION: The maximum operating temperature of the installed applicator
and the other heated components should be considered when setting
temperatures on the melter control panel.
Conditioning Compressed Air for Applicator Control Modules
The quality of the compressed air must be at least class 2 in compliance with
ISO 8573-1. This means:
Max. particle size 1 m
Max. particle density 1 mg/m
3
Max. pressure dew point -40°C / -40°F
Max. oil concentration 0.1 mg/m
3
.
Connecting Filling Valve (Option)
1. Connect customer's compressed air supply to the control air connection
(2).
4 to max. 6 bar 400 to max. 600 kPa 58 to max. 87 psi
NOTE: The compressed air must be dry and non-lubricated. Dirt particles in
the air may not exceed 30 m in size.
2. Electrically/mechanically connect hose to the filling unit.
3. Connect the hose to the filling valve connection (1, Fig. 3‐9) (Also refer to
Fig. 3‐8).
The filling valve is heated either via the VersaBlue melter or via the filling unit
(e.g. bulk melter).
4. If the heater is not controlled via the VersaBlue melter, insert the voltage
plug into the hose receptacle.