EasyManua.ls Logo

Nordson VersaBlue VA - Important When Using the Seven-Day Clock (Example of a Schedule)

Nordson VersaBlue VA
272 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mo
00:00 06:00 12:00 18:00 23:00
Tu
We
Th
Fr
Sa
Su
Thursday, 2005-09-08 07:51:46
Operation
4‐47
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Melter (contd.)
Overview
Gray: Heaters off / standby off
Yellow: Enter standby
Green: Heaters on
NOTE: The programmed times are shown, not the melter mode.
Set Date / Time
The current date and time can be set with the +/- keys.
The date is shown in the following format: YYYY-MM-DD (Y: year; M: month;
D: day)
NOTE: The time is not automatically changed to and from daylight savings
time.
Important when Using the Seven‐day Clock (Example of
a Schedule)
Heaters on 08:00
Enter standby 12:00
Exit standby 13:00
Heaters off 17:00
If the seven-day clock is not switched on until after 08:00 (key
), the
switching time 08:00 has already passed; the heater is not switched on by
the seven-day clock. The schedule is ineffective.

Table of Contents