Customer setup
Fig. 4‐49
V7
Mo WeTu Th Fr Sa Su
Clear
Edit
schedule
Copy
schedules
Overview
Enter standby Exit standby
1
2
3
4
02:00 06:00 06:30
12:00 13:00
22:00
15:00 15:30
19:00 19:30
Heaters on Heaters off
Fig. 4‐50
V8: Main screen
1
Enter
standby
Exit standby
02:00
06:00
06:30
Monday
Schedule
Heaters on
Heaters off
Clear
Mo WeTu Th Fr Sa Su
Operation
4‐46
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Melter (contd.)
Setup (Screen 1: Seven‐day Clock, Standby, Inert
Gas, Changing Language, Recipes, Level)
Seven-day Clock
Heaters and standby can be controlled via the seven-day clock. Up to four
schedules that run at the same time can be stored for each day of the week.
Clear: All of the schedules for the marked day (in this case: Monday) will be
deleted.
Editing Schedule
The times are entered by row. The corresponding key must be activated to
be able to enter a time.
NOTE: 00:00 is a valid time; it does not mean that this feature is switched
off.
Delete (individual schedules): The displayed schedule is deleted.
Copying Schedules (Example: Copy schedules for Monday to Tuesday and
Friday)
1. Select
Mo
in the main screen.
2.
Schedule
copy
: A window opens in which the days Tuesday and Friday have to
be marked.
3. Confirm selection with .
The schedules have been copied.