Profibus address
10
Control
panel
Standard I/O
No field bus
Fig. 4‐72
Profibus address
10
No control
panel
Field bus
No standard
I/O
Fig. 4‐73
Operation
4‐58
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Melter (contd.)
Control Modes
Standard
Control access from control panel and from external control signals via
the interfaces or the IPC Webserver
Parameter input only via control panel
Line speed signal input via interface Key-to-line (XS5).
Field bus
Control access only from master
Control via the IPC Webserver and the interface Standard I/O is not
possible
Parameter input only via master On the control panel, parameters can
only be displayed; there are a few exceptions.
Exceptions:
Brightness (and contrast)
Date / time
Local language
PROFIBUS address
Control mode
Software version V5.02.004 and higher: Line speed signal input via the
interface Key‐to‐line (XS5) or via the field bus.