Maintenance
5‐2
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Processing Materials
Designation Order number Use
High temperature grease To be applied to O-rings, threads
and sealing surfaces
NOTE: The grease may not be
mixed with other lubricants.
Oily/greasy parts must be cleaned
before application.
Can 10 g
P/N 394769
Tube 250 g
P/N 783959
Cartridge 400 g
P/N 402238
Temperature-resistant
adhesive Loctite 640
Secures screw connections
50 ml
P/N 290359
Heat transfer compound
NTE303
To improve heat conducting of
temperature sensors
1 g
P/N 1023441
Preventive Maintenance
The maintenance intervals are general guidelines based on experience.
Depending on the operating environment, production conditions and melter
hours of operation, other scheduled maintenance tasks may prove
necessary.
Resetting Maintenance Interval
When the time that the customer has defined as the Maintenance interval
has elapsed, a warning is indicated (software version 6.47.035 and higher)
and the maintenance symbol (wrench) lights up.
RESET: The timer for the service interval is reset, the warning is revoked,
and the service symbol is switched off.
NOTE: Coupling and motor controller are maintenance-free.
Melter part
Activity Interval Refer to page
Complete melter External cleaning Daily 5‐4
Visual inspection for
external damage
Daily 5‐5
Purge melter with
cleaning agent
When material is changed 5‐20
Displays and lamps Safety and function tests Daily 5‐5
Fan and
Air filter
Check filter, clean or
replace if necessary
Clean fan screen
Depending on dust
accumulation; daily if necessary
5‐6
Power cable Inspect for damage Every time the melter is serviced -
Air hoses Inspect for damage Every time the melter is serviced -