Maintenance
5‐8
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Motor
The only motor maintenance required is cleaning the fan cap.
Gear Box
Selecting Lubricant
NOTE: Use only the stated lubricant or one that has proven to be equivalent
(Refer to Lubricants). Using any other lubricant can result in premature wear
and/or damage to the gear box.
Lubricants
Lubricant manufacturer Mineral oil CLP 220
AGIP Blasia 220
ARAL Degol BMB 220 or Degol BG 220
BP Energol GR‐XP 220
DEA Falcon CLP 220
ESSO Spartan EP 220 or GP 90
KLÜBER Klüberoil GEM 1‐220
OPTIMOL Optigear 220
SHELL Omala Oil 220
TEXACO Geartex EP‐A SAE 85 W‐90
Lubricant Changing Interval
Lubricant temperatures below 100°C / 212°F:
Every 15000 hours of operation or at least every 4 years.
Capacity
The lubricant quantity is indicated on the ID plate. Ensure that the upper
gears and rolling bearings are properly lubricated.