Each kit contains a temperature sensor and heat transfer compound.
Required tools:
Pliers
Side cutting pliers
V025
1. Remove electrical equipment cover.
2. Disconnect connecting wires and extract old temperature sensor by the
connecting wires or with the aid of a pliers.
3. Apply heat transfer compound to new sensor.
4. Insert sensor and reconnect electrically.
5. Attach electrical equipment cover again.