Technical Data
9‐2
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Temperatures
CAUTION: The maximum operating temperature of the installed gun and the
other heated components should be considered when setting temperatures
on the melter control panel.
Min. operating temperature
(setpoint)
40°C 100°F
Max. operating
temperatures for standard
melters
Ni120 temperature sensor
230°C 450°F
Pt 100Ni120
Hose connections
Max. operating
temperatures for high
temperature melters
Pt100 temperature sensor
250°C 480°F
Overtemperature shutdown
by thermostat
260°C
288°C
500°F
550°F
Standard melter
High‐temperature melter
Shutdown by transformer
thermostat
155°C
(± 5°C)
311°F
(±9°F)
Max. operating temperature
of filling valve (option)
230°C 450°F
Electrical Data
ATTENTION: The unit is designed for only one operating voltage. Operate
only at the operating voltage shown on the ID plate.
Available operating
voltages
200 V
AC
3‐phase without neutral (- Delta)
230 V
AC
3‐phase without neutral (- Delta)
400 V
AC
3-phase with neutral (star - WYE)
400 V
AC
3‐phase without neutral (- Delta)
480 V
AC
3‐phase without neutral (- Delta)
Only with V12: 230 V
AC
1‐phase with neutral
Permissible voltage
deviations
Power supply:
Standard I/O:
± 10%
± 10%
Operating voltage
frequency
50/60 Hz
SCCR* 10 kA
Melter fuse protection Refer to ID plate
Key‐to‐line
Max. input
0 to 10 V
DC
0 to 20 mA
4 to 20 mA
0 to 100 kHz