EasyManua.ls Logo

Nordson VersaBlue VA - Temperatures; Electrical Data

Nordson VersaBlue VA
272 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Data
9‐2
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Temperatures
CAUTION: The maximum operating temperature of the installed gun and the
other heated components should be considered when setting temperatures
on the melter control panel.
Min. operating temperature
(setpoint)
40°C 100°F
Max. operating
temperatures for standard
melters
Ni120 temperature sensor
230°C 450°F
Pt 100Ni120
Hose connections
Max. operating
temperatures for high
temperature melters
Pt100 temperature sensor
250°C 480°F
Overtemperature shutdown
by thermostat
260°C
288°C
500°F
550°F
Standard melter
High‐temperature melter
Shutdown by transformer
thermostat
155°C
(± 5°C)
311°F
(±9°F)
Max. operating temperature
of filling valve (option)
230°C 450°F
Electrical Data
ATTENTION: The unit is designed for only one operating voltage. Operate
only at the operating voltage shown on the ID plate.
Available operating
voltages
200 V
AC
3‐phase without neutral (- Delta)
230 V
AC
3‐phase without neutral (- Delta)
400 V
AC
3-phase with neutral (star - WYE)
400 V
AC
3‐phase without neutral (- Delta)
480 V
AC
3‐phase without neutral (- Delta)
Only with V12: 230 V
AC
1‐phase with neutral
Permissible voltage
deviations
Power supply:
Standard I/O:
± 10%
± 10%
Operating voltage
frequency
50/60 Hz
SCCR* 10 kA
Melter fuse protection Refer to ID plate
Key‐to‐line
Max. input
0 to 10 V
DC
0 to 20 mA
4 to 20 mA
0 to 100 kHz
* SCCR isthe abbreviation for: Short Circuit Current Rating.