Motor OFF delay
Threshold switch
Stop at
0.0
0.0
Not
enabled
Start at
Fig. 4‐98
M4
Operation
4‐70
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Motor (contd.)
Parameters (Screen 3: Motor OFF Delay, Threshold
Switch)
Motor OFF Delay:
The motor OFF delay supports overtravel when identifying the product, if the
sensor distance to the applicator needs to be considered.
Fig. 4‐99 Product identification
If this feature is not activated (delay = 0 s), the motor stops as soon as it is
switched off.
If this feature is activated, the motor continues to run for the set time after it
has been turned off via the interface Standard I/O.
NOTE: If the motor is switched on via the Standard I/O interface before the
motor OFF delay has expired, the Motor OFF delay ends immediately.