EasyManua.ls Logo

Nordson VersaBlue VA - Pressure Control Valve; Installing Service Kit

Nordson VersaBlue VA
272 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance
5‐10
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Pressure Control Valve
ATTENTION: Hot! Risk of burns. Wear appropriate protective
clothing/equipment.
ATTENTION: System and material pressurized. Relieve system pressure.
Failure to observe can result in serious burns.
NOTE: Screw in/out only when valve is warm and material is soft (approx.
70°C/158°F, depending on material).
Installing Service Kit
Each kit contains two O‐rings and high‐temperature grease.
Mechanical pressure control valve Pneumatic pressure control valve (option)
Required tool:
Open‐end wrench, size 24
Pliers
Torque wrench
Required tools:
Open‐end wrench, size 27
Pliers
Torque wrench
1. Heat melter to operating temperature.
ATTENTION: Hot! Risk of burns. Wear appropriate protective
clothing/equipment.
2. Relieve melter pressure.
-
3. Close compressed air supply.
4. Refer to Measuring Insertion Depth
4. Unscrew air hose.
5. Use an open-end wrench to screw out the pressure control valve, then extract with
a pliers.
If the tank is not empty:
Collect any adhesive that may escape (bowl).
Quickly screw in a replacement pressure control valve or a plug, then perform
maintenance work.
6. Remove old O‐rings, and disassemble and clean pressure control valve. Refer to
separate Parts List for detailed drawing of the valve.
NOTE: Disassemble valve only when warm.
7. Install new O-rings. Apply grease to all threads and O-rings.
8. Guide pressure control valve into the bore when the melter is warm and tighten with
torque wrench.
Torque: 15 Nm (133 lbin)
9. Refer to Adjusting Setting Screw
9. Attach air hose.
-
10. Open compressed air supply again.

Table of Contents

Related product manuals